• Users Online: 280
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 12  |  Issue : 3  |  Page : 147-152

Bone marrow aspiration using 18g lumbar puncture needle: Can it be an alternative to conventional bone marrow needle?


1 Department of Oncopathology, Acharya Harihar Postgraduate Institute of Cancer, Cuttack, Odisha, India
2 Department of Pathology, SCB Medical College and Hospital, Cuttack, Odisha, India
3 Department of Pathology, KIMS, Bhubaneswar, Odisha, India

Correspondence Address:
Mr. Sashibhusan Dash
Department of Oncopathology, Acharya Harihar Postgraduate Institute of Cancer, 3rd Floor, Annex Building, Cuttack - 753 007, Odisha
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/joah.joah_190_20

Rights and Permissions

INTRODUCTION: Bone marrow aspiration (BMA) has an important role in the investigation and diagnosis of hematologic as well as nonhematologic malignancies and various other diseases. The procedure varies from one setting and person to the other. AIMS: The aim of the study is to study the role of 18G lumbar puncture (LP) needle in the diagnosis of bone marrow involvement in hematologic malignancies and metastasis for certain solid tumors. MATERIALS AND METHODS: During this hospital-based retrospective study, 708 patients who clinically and histopathologically diagnosed with the malignant lesion and subsequently undergone BMA were included in this study. RESULTS: BMA was done in 607 patients diagnosed with hematologic malignancies and 101 patients diagnosed with nonhematologic malignancies. Adequate marrow material was obtained in the first attempt in 683 (96.5%) cases. Multiple aspirations were needed in 25 (3.5%) cases. The majority (86.3%) of the patients experienced less pain by the 18 G LP needle compared to their previous experience with the conventional BMA needle. Needle breakage was not seen in any of the cases. CONCLUSION: The results of this study suggest that the 18G LP needle can be easily adopted for BMA and could be a great help in significantly reducing pain and complications in patients undergoing BMA.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed682    
    Printed14    
    Emailed0    
    PDF Downloaded81    
    Comments [Add]    

Recommend this journal